24/11/2024

OS1 RapidNet MTP 72 Fibre 6 MTP Cassette to MTP Fan Out
Številka proizvoda 860-00158 | RNFT672-MCMDS1-10.0M Podrobnosti

  • Up to 288 fibres in 1U of Space
  • High performance low loss Elite® connectors from US Conec
  • 40G and 100G ready
  • Significantly reduced installation times
  • Available in OM3, OM4, OS2 and OS1
  • Dual labelling fields
  • Interchangeable with other RapidNet Cassettes
  • Pre-tested with test results supplied
prikaži več izdelkov

Zahtevajte svojo individualno ponudbo zdaj

Connector Type MTP
Description The RapidNet MTP VHD Cassette to MTP Fan Out is pre-terminated with the cassette presenting six 12 core MTP connectors at one end and a fan out of six 12 core MTP connectors at the other end, which enables up to 288 fibres in 1U of rack space, with 4 cassettes fitting into a RapidNet Patch Panel. The RapidNet MTP VHD solution has been designed to meet the demands of the data centre by providing reduced installation times, efficient use of space, flexible configurations and high performance. This high density fibre solution is particularly suited to use in Storage Area Network (SAN) applications.
PART DESCRIPTION RNFT672-MCMDS1-10.0M
Performance Category OS1 Single Mode
Port count 6
Product Family 6 MTP Cassette to MTP Fan Out
Product Group RapidNet MTP 72 Fibre
Short Description OS1 RapidNet MTP 72 Fibre 6 MTP Cassette to MTP Fan Out
Technical Description The use of high performance low loss Elite® MTP connectors from US Conec as standard minimises losses across the link and provides a potential upgrade path from 10G through to 40G and 100G. The cassette is manufactured with a single push clip mechanism and polarising clips to prevent incorrect insertion. Fibre Optic management is provided within the RapidNet Cassette with integral strain relief which provides protection to all the cables and their terminations. The individual fibres within the cassette are managed using positive bend radius management to ensure minimum losses and maximum performance. All RapidNet terminations are tested to exceed the latest published versions of ISO/IEC 11801, BS/EN50173 and ANSI/TIA/EIA 568 – C standards. NB. Part Numbers given are for a 10m loom as an example. Other lengths are available on request that meet the maximum distance performances defined in the latest published versions of ISO/IEC 11801, BS/EN50173 and ANSI/TIA/EIA 568 – C. The standard fan out breakout is 0.5m for loom lengths between 2m to 5m and 1m for loom lengths over 5m.
Type RNFT672-MCMDS1-10.0M
Depth (D) 130mm
Height (H) 27mm
Length (L) 10.0m
Width (W) 102mm
Country of Origin GB
Dimensions W x H x D 102 mm x 27 mm x 130 mm
GTIN-13 / EAN 4031026451886

Zahtevajte svojo individualno ponudbo zdaj